P1000 Drive

P1000 Drive
P1000 Drive

P1000 Drive 3/4 – 1000 HP

The P1000 drive provides simple, reliable, cost-effective control for variable-torque loads through 1000 HP. Specific application features, energy savings, and network connectivity make the P1000 a great choice for industrial fans and pumps.

P1000 Drive Features

LCD Operator with Real Time Clock

  • 5-line, 16-character alpha-numeric display with time and date stamping for events, along with timer controls for starting, stopping, and speed changes without the need for external controls.

Application Macros

  • Choose from pre-configured fan and pump setup macros to match the application for quick and easy set up.

Selectable and Custom Engineering Units

  • Allows for easy configuration of keypad display to match process and feedback devices such as PSI, GPM, Feet.

Underload Detection

  • Monitors load and will shut system down in the event of a fan belt or pump shaft breakdown.

Parameter Storage and Removable Terminal Board

  • Allows for easy replacement of control card without removing control wires, and stores all drive settings without the need for a copy device.

PI Process Control

  • Maintains a set point for closed loop control of fans and pumps for pressure, flow, or temperature regulation, and eliminates the need for a closed loop output signal from a process controller. Independent PI to control an external device in the system.

Power Quality

  • Built-in DC reactors (30 HP and larger) provide input harmonics benefit, and protection from input disturbances. Integrated 12 Pulse version (480V, 40 HP and larger) provides a cost-effective solution for low harmonics.

Dynamic Noise Control

  • Monitors the load at all times and reduces the output voltage automatically, reducing motor audible noise.

Networking Options

  • Industrial Communication
    • Modbus RTU (built-in)
    • DeviceNet
    • EtherNet/IP
    • Modbus TCP/IP
    • PROFIBUS-DP
    • PROFINET
  • Building Automation Networks (BAS)
    • BACnet
    • Lonworks
    • Metasys (N2)
    • Apogee (P1

P1000 Drive Specifications

Item Specification
Continuous Load Capacity Variable Torque (square of percent speed)
Intermittent Load Capacity 120% for 60 seconds
Output Frequency 0.01 to 400 Hz
Enclosure Solutions Open Type/IP00
NEMA Type 1(kit required for some models)
IFlange Type (front = Open/IP00, back = NEMA Type 12)
Power Solutions 6-pulse (standard)
240V: 3/4 to 175 HP
480V: 1 to 1000 HP
600V: 1 to 250 HP12-pulse (low harmonic)
480V: 40 to 1000 HP
Ambient Operating Temperature -10°C to 40°C (14°F to 104°F)
Global Certification UL, CSA, CE, RoHS, C-Tick
Standard I/O (8) multi-function digital inputs (24Vdc)
(3) multi-function analog inputs (0-10 VDC, 4-20 mA)
(1) multi-function pulse input
(1) fault relay output (form C)
(1) multi-function relay (form C)
(2) multi-function relay outputs (form A)
(2) multi-function analog outputs (0 +/- 10 VDC, 4-20mA)
Sensor feedback power supply (+24VVdc at 150mA supply)
120V converter for 8 standard digital inputs (option)

P1000 Drive Models & Ratings

P1000 Drive 200-240V, 3-Phase, Standard

Drive Model Number Rated Output Current (Amps) Nominal HP 3 Standard Enclosure 1, 2
CIMR-PU2A0004FAA 3.5 3/4 NEMA 1
CIMR-PU2A0006FAA 6 1
CIMR-PU2A0008FAA 8 2
CIMR-PU2A0010FAA 9.6 2 NEMA 1
CIMR-PU2A0012FAA 12 3
CIMR-PU2A0018FAA 17.5 5
CIMR-PU2A0021FAA 21 7.5 NEMA 1
CIMR-PU2A0030FAA 30 10
CIMR-PU2A0040FAA 40 15
CIMR-PU2A0056FAA 56 20 NEMA 1
CIMR-PU2A0069FAA 69 25
CIMR-PU2A0081FAA 81 30
CIMR-PU2A0110FAA 110 40 NEMA 1
CIMR-PU2A0138FAA 138 50
CIMR-PU2A0169FAA 169 60 NEMA 1
CIMR-PU2A0211FAA 211 75
CIMR-PU2A0250AAA 250 100 Protected Chassis
CIMR-PU2A0312AAA 312 125
CIMR-PU2A0360AAA 360 150 Protected Chassis
CIMR-PU2A0415AAA 415 175
  1. Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU2A081FAA and smaller).
  2. Only models ending in FAA (CIMR-PU2A0211FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
  3. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.

P1000 Drive 200-240V, 1-Phase, Standard

Drive Model Number 1, 2 Single Phase Input – Sizing Method AA
(Continuous Full Power)
Single Phase Input – Sizing Method BB
(86% max power of connected motor size)
Without Additional Reactor With Additional Reactor Motor Amps Motor Size (HP)
Motor Amps Motor Size (HP) Motor Amps Motor Size (HP)
CIMR-PU2A0004FAA 1.7 1/3 2.4 1/2 3.5 1/2
CIMR-PU2A0006FAA 3.5 3/4 3.5 3/4 4.6 1
CIMR-PU2A0008FAA 4.6 1 4.6 1 6.6 1
CIMR-PU2A0010FAA 4.6 1 4.6 1 6.6 1.5
CIMR-PU2A0012FAA 6.6 1.5 7.5 2 7.5 2
CIMR-PU2A0018FAA 7.5 2 10.6 3 10.6 3
CIMR-PU2A0021FAA 7.5 2 10.6 3 10.6 3
CIMR-PU2A0030FAA 10.6 3 10.6 3 17 5
CIMR-PU2A0040FAA 10.6 3 17 5 17 5
CIMR-PU2A0056FAA 17 5 24 7.5 24 7.5
CIMR-PU2A0069FAA 24 7.5 31 10 31 10
CIMR-PU2A0081FAA 31 10 46 15 46 15
CIMR-PU2A0110FAA 31 10 31 10 46 15
CIMR-PU2A0138FAA 46 15 46 15 59 20
CIMR-PU2A0169FAA 59 20 59 20 75 25
CIMR-PU2A0211FAA 75 25 75 25 88 30
CIMR-PU2A0250AAA 88 30 88 30 114 40
CIMR-PU2A0312AAA 114 40 114 40 143 50
CIMR-PU2A0360AAA 143 50 143 50 169 60
CIMR-PU2A0415AAA 169 60 169 60 211 75
  1. Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU2A0081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
  2. Only models ending in FAA (CIMR-PU2A0211FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
  3. For Flange Drives, use the Sizing Method above to determine proper drive size. Use selected model number with “UAA” suffix instead of “FAA” or “AAA” suffix.

    (A) Use single-phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” under P1000 Power Options on this site. Caution: Adding more impedance than specified will degrade performance.
    (B) Use single-phase input sizing method B for applications requiring a maximum of 86% motor power.

P1000 Drive 200-240V, 3-Phase, Flange

Drive Model Number 1 Rated Output Current (Amps) Nominal HP 2 Enclosure 1
CIMR-PU2A0004UAA 3.5 3/4 Flange
CIMR-PU2A0006UAA 6 1
CIMR-PU2A0008UAA 8 2
CIMR-PU2A0010UAA 9.6 3 Flange
CIMR-PU2A0012UAA 12 3
CIMR-PU2A0018UAA 17.5 5
CIMR-PU2A0021UAA 21 7.5 Flange
CIMR-PU2A0030UAA 30 10
CIMR-PU2A0040UAA 40 15
CIMR-PU2A0056UAA 56 20 Flange
CIMR-PU2A0069UAA 69 25
CIMR-PU2A0081UAA 81 30
CIMR-PU2A0110UAA 110 40 Flange
CIMR-PU2A0138UAA 138 50
CIMR-PU2A0169UAA 169 60
CIMR-PU2A0211UAA 211 75 Flange
CIMR-PU2A0250UAA 250 100
CIMR-PU2A0312UAA 312 125
CIMR-PU2A0360UAA 360 150 Flange
CIMR-PU2A0415UAA 415 175
  1. Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
  2. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.

P1000 Drive 380-480V, 3-Phase, Standard

Drive Model Number Rated Output Current (Amps) Nominal HP 3 Standard Enclosure 1, 2
CIMR-PU4A0002FAA 2.1 1 NEMA 1
CIMR-PU4A0004FAA 4.1 2
CIMR-PU4A0005FAA 5.4 3
CIMR-PU4A0007FAA 6.9 4 NEMA 1
CIMR-PU4A0009FAA 8.8 5
CIMR-PU4A0011FAA 11.1 7.5
CIMR-PU4A0018FAA 17.5 10 NEMA 1
CIMR-PU4A0023FAA 23 15
CIMR-PU4A0031FAA 31 20
CIMR-PU4A0038FAA 38 25 NEMA 1
CIMR-PU4A0044FAA 44 30
CIMR-PU4A0058FAA 58 40
CIMR-PU4A0072FAA 72 50 NEMA 1
CIMR-PU4A0088FAA 88 60
CIMR-PU4A0103FAA 103 75
CIMR-PU4A0139FAA 139 100 NEMA 1
CIMR-PU4A0165FAA 165 125
CIMR-PU4A0208AAA 208 150 Protected Chassis
CIMR-PU4A0250AAA 250 200
CIMR-PU4A0296AAA 296 250
CIMR-PU4A0362AAA 362 300 Protected Chassis
CIMR-PU4A0414AAA 414 350
CIMR-PU4A0515AAA 515 400 Protected Chassis
CIMR-PU4A0675AAA 675 500
CIMR-PU4A0930AAA 930 700-800 Protected Chassis
CIMR-PU4A1200AAA 1200 900-1000
  1. Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU4A044FAA and smaller).
  2. Only models ending in FAA (CIMR-PU4A0165FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
  3. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
  4. Models CIMR-PU4A0930AAA and CIMR-PU4A1200AAA must be used with semiconductor input fuses and must be fed by a power source that has ground fault protection. A supplementary ground fault protection device can be added between the drive and the power source to address this requirement.

P1000 Drive 380-480V, 1-Phase, Standard

Drive Model Number 1, 2 Single Phase Input – Sizing Method AA
(Continuous Full Power)
Single Phase Input – Sizing Method BB
(86% max power of connected motor size)
Without Additional Reactor With Additional Reactor Motor Amps Motor Size (HP)
Motor Amps Motor Size (HP) Motor Amps Motor Size (HP)
CIMR-PU4A0002FAA 0.8 1/3 1.1 1/2 1.6 3/4
CIMR-PU4A0004FAA 1.6 3/4 2.1 1 2.1 1
CIMR-PU4A0005FAA 2.1 1 3 1.5 3.4 2
CIMR-PU4A0007FAA 3.0 1.5 3.4 2 3.4 2
CIMR-PU4A0009FAA 3.4 2 4.8 3 4.8 3
CIMR-PU4A0011FAA 3.4 2 4.8 3 4.8 3
CIMR-PU4A0018FAA 4.8 3 4.8 3 7.6 5
CIMR-PU4A0023FAA 4.8 3 7.6 5 7.6 5
CIMR-PU4A0031FAA 11 7.5 11 7.5 14 10
CIMR-PU4A0038FAA 11 7.5 14 10 14 10
CIMR-PU4A0044FAA 14 10 14 10 21 15
CIMR-PU4A0058FAA 21 15 21 15 27 20
CIMR-PU4A0072FAA 27 20 27 20 34 25
CIMR-PU4A0088FAA 27 20 27 20 34 25
CIMR-PU4A0103FAA 27 20 27 20 34 25
CIMR-PU4A0139FAA 52 40 52 40 65 50
CIMR-PU4A0165FAA 52 40 52 40 65 50
CIMR-PU4A0208AAA 65 50 65 50 77 60
CIMR-PU4A0250AAA 77 60 77 60 96 75
CIMR-PU4A0296AAA 96 75 96 75 124 100
CIMR-PU4A0362AAA 124 100 124 100 156 125
CIMR-PU4A0414AAA 156 125 156 125 180 150
CIMR-PU4A0515AAA 156 125 156 125 180 150
CIMR-PU4A0675AAA 180 150 180 150 240 200
  1. Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU4A0044FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
  2. Only models ending in FAA (CIMR-PU4A0165FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
  3. For Flange Drives, use the Sizing Method above to determine proper drive size. Use selected model number with “UAA” suffix instead of “FAA” or “AAA” suffix.

    (A) Use single-phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” under P1000 Power Options on this site. Caution: Adding more impedance than specified will degrade performance.
    (B) Use single-phase input sizing method B for applications requiring a maximum of 86% motor power.

P1000 Drive 380-480V, 3-Phase, Flange

Drive Model Number1

Rated Output Current (Amps)

Nominal HP2 Enclosure1
CIMR-PU4A0002UAA 2.1 1 Flange
CIMR-PU4A0004UAA 4.1 2
CIMR-PU4A0005UAA 5.4 3
CIMR-PU4A0007UAA 6.9 4 Flange
CIMR-PU4A0009UAA 8.8 5
CIMR-PU4A0011UAA 11.1 7.5
CIMR-PU4A0018UAA 17.5 10 Flange
CIMR-PU4A0023UAA 23 15
CIMR-PU4A0031UAA 31 20
CIMR-PU4A0038UAA 38 25 Flange
CIMR-PU4A0044UAA 44 30
CIMR-PU4A0058UAA 58 40
CIMR-PU4A0072UAA 72 50 Flange
CIMR-PU4A0088UAA 88 60
CIMR-PU4A0103UAA 103 75
CIMR-PU4A0139UAA 139 100 Flange
CIMR-PU4A0165UAA 165 125
CIMR-PU4A0208UAA 208 150 Flange
CIMR-PU4A0250UAA 250 200
CIMR-PU4A0296UAA 296 250
CIMR-PU4A0362UAA 362 300 Flange
CIMR-PU4A0414UAA 414 350
CIMR-PU4A0515UAA 515 400 Flange
CIMR-PU4A0675UAA 675 500
CIMR-PU4A0930UAA3 930 700-800 Flange
CIMR-PU4A1200UAA3 1200 900-1000
  1. Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
  2. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
  3. Models CIMR-PU4A0930UAA and CIMR-PU4A1200UAA must be used with semiconductor input fuses and must be fed by a power source that has ground fault protection. A supplementary ground fault protection device can be added between the drive and the power source to address this requirement.

P1000 Drive 380-480V, 3-Phase, 12-Pulse Flange

Drive Model Number 12-Pulse1 Rated Output Current (Amps) Nominal HP2 Enclosure1
CIMR-PU4T0058UAA 58 40 Flange
CIMR-PU4T0072UAA 72 50
CIMR-PU4T0088UAA 88 60 Flange
CIMR-PU4T0103UAA 103 75
CIMR-PU4T0139UAA 139 100 Flange
CIMR-PU4T0165UAA 165 125
CIMR-PU4T0208UAA 208 150 Flange
CIMR-PU4T0250UAA 250 200
CIMR-PU4T0296UAA 296 250
CIMR-PU4T0362UAA 362 300 Flange
CIMR-PU4T0414UAA 414 350
CIMR-PU4T0515UAA 515 400 Flange
CIMR-PU4T0675UAA 675 500
See note 3 930 700-800 Flange
See note 3 1200 900-1000
  1. Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external. Flange parts can be removed if convential mounting is desired.
  2. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
  3. Models CIMR-PU4A0930xxx and CIMR-PU4A1200xxx are user configurable for either 6-Pulse (3-Phase) or 12-Pulse (6-Phase) input. See Standard 480V for model numbers.

P1000 Drive 500-600V, 3-Phase, Standard

Drive Model Number Rated Output Current (Amps) Nominal HP 3 Standard Enclosure 1, 2
CIMR-PU5A0003FAA 2.7 1 & 2 NEMA 1
CIMR-PU5A0004FAA 3.9 3
CIMR-PU5A0006FAA 6.1 5
CIMR-PU5A0009FAA 9 7.5 NEMA 1
CIMR-PU5A0011FAA 11 10
CIMR-PU5A0017FAA 17.5 15
CIMR-PU5A0022FAA 22 20 NEMA 1
CIMR-PU5A0027FAA 27 25
CIMR-PU5A0032FAA 32 30
CIMR-PU5A0041FAA 41 40 NEMA 1
CIMR-PU5A0052FAA 52 50
CIMR-PU5A0062FAA 62 60
CIMR-PU5A0077FAA 77 75 NEMA 1
CIMR-PU5A0099FAA 99 100
CIMR-PU5A0125AAA 125 125 Protected Chassis
CIMR-PU5A0145AAA 145 150
CIMR-PU5A0192AAA 192 200 Protected Chassis
CIMR-PU5A0242AAA 242 250
  1. Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU5A032FAA and smaller).
  2. Only models ending in FAA (CIMR-PU5A0099FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
  3. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.

P1000 Drive 500-600V, 1-Phase, Standard

Drive Model Number 1, 2 Single Phase Input – Sizing Method AA
(Continuous Full Power)
Single Phase Input – Sizing Method BB
(86% max power of connected motor size)
Without Additional Reactor With Additional Reactor Motor Amps Motor Size (HP)
Motor Amps Motor Size (HP) Motor Amps Motor Size (HP)
CIMR-PU5A0003FAA 1.7 1 2.4 1.5 1.7 1
CIMR-PU5A0004FAA 2.4 1.5 2.7 2 2.7 2
CIMR-PU5A0006FAA 2.7 2 3.9 3 3.9 3
CIMR-PU5A0009FAA 3.9 3 6.1 5 6.1 5
CIMR-PU5A0011FAA 2.7 2 3.9 3 3.9 3
CIMR-PU5A0017FAA 6.1 5 6.1 5 9 7.5
CIMR-PU5A0022FAA 6.1 5 9 7.5 9 7.5
CIMR-PU5A0027FAA 9 7.5 11 10 11 10
CIMR-PU5A0032FAA 9 7.5 11 10 11 10
CIMR-PU5A0041FAA 17 15 17 15 22 20
CIMR-PU5A0052FAA 17 15 17 15 22 20
CIMR-PU5A0062FAA 27 25 27 25 32 30
CIMR-PU5A0077FAA 32 30 32 30 41 40
CIMR-PU5A0099FAA 32 30 32 30 41 40
CIMR-PU5A0125AAA 52 50 52 50 62 60
CIMR-PU5A0145AAA 52 50 52 50 62 60
CIMR-PU5A0192AAA 77 75 77 75 99 100
CIMR-PU5A0242AAA 77 75 77 75 99 100
  1. Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU5A0032FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
  2. Only models ending in FAA (CIMR-PU5A0099FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
  3. For Flange Drives, use the Sizing Method above to determine proper drive size. Use selected model number with “UAA” suffix instead of “FAA” or “AAA” suffix.(A) Use single-phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” under P1000 Power Options on this site. Caution: Adding more impedance than specified will degrade performance.
    (B) Use single-phase input sizing method B for applications requiring a maximum of 86% motor power.

P1000 Drive 500-600V, 3-Phase, Flange

Drive Model Number1 Rated Output Current (Amps) Nominal HP2 Enclosure1
CIMR-PU5A0003UAA 2.7 1 & 2 Flange
CIMR-PU5A0004UAA 3.9 3
CIMR-PU5A0006UAA 6.1 5
CIMR-PU5A0009UAA 9 7.5 Flange
CIMR-PU5A0011UAA 11 10
CIMR-PU5A0017UAA 17.5 15
CIMR-PU5A0022UAA 22 20 Flange
CIMR-PU5A0027UAA 27 25
CIMR-PU5A0032UAA 32 30
CIMR-PU5A0041UAA 41 40 Flange
CIMR-PU5A0052UAA 52 50
CIMR-PU5A0062UAA 62 60
CIMR-PU5A0077UAA 77 75 Flange
CIMR-PU5A0099UAA 99 100
CIMR-PU5A0125UAA 125 125 Flange
CIMR-PU5A0145UAA 145 150
CIMR-PU5A0192UAA 192 200 Flange
CIMR-PU5A0242UAA 242 250
  1. Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external. Flange parts can be removed if conventional mounting is desired.
  2. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
  3. Models CIMR-PU4A0930xxx and CIMR-PU4A1200xxx are user configurable for either 6-Pulse (3-Phase) or 12-Pulse (6-Phase) input. See Standard 480V price page on page 4 for model numbers and prices.

Biến tần yaskawa P1000 Drive

Sản phẩm liên quan

Nhận báo giá thiết bị Yaskawa chính hãng

Tư vấn chọn model – Giao hàng toàn quốc – Bảo hành 12 tháng

Gọi 0904 828 747 Liên hệ