Z1000 Drive
Z1000 Drive 3 – 500 HP
The Z1000 variable speed drive is designed for building automation applications such as fans, pumps, and cooling towers through 500HP. The Z1000 features an easy-to-read LCD keypad that provides Hand-Off-Auto interface and a real time clock. These features make the Z1000 perfect for many building automation applications that require reliable motor control.
Z1000 Drive Features
Harmonic Mitigation:
- Built-in 5% line impedance for input harmonic reduction.
Noise Filter:
- On board EMI/RFI filter complies with IEC 61800-3 restricted distribution for first environment.
Serial Communications:
- Embedded BACnet communications (BTL Certified), along with Modbus/Memobus, Metasys and Apogee FLN.
Ratings:
- Plenum Rated (UL 1995). Seismic Rated (IBC 2006 – Certification 12/2011). Made with RoHS compliant materials.
Internal Real-Time Clock:
- Time and date stamping for events, along with timer controls for starting, stopping, and speed changes without the need for external controls.
PI Feature:
- Maintains a set point for closed loop control of fans and pumps for pressure, flow or temperature regulation and eliminates the need for a closed loop output signal from a BAS. Independent PI to control an external device in the system.
LCD Operator:
- 5-Line 16 character alpha-numeric, easy to read and understand display, with Hand-Off-Auto functions.
Carrier Frequency:
- 5 kHz carrier frequency with dynamic noise control for quiet motor operation.
Application Macros:
- Choose from pre-configured set up macros to match the application for quick and easy set up.
Sealed Heatsink:
- Allows for drive to be mounted in a NEMA 12 enclosure with heatsink external.
Z1000 Drive Specifications
Additional specifications can be found within the Z1000 User Manual (Doc# TOEPC71061645) under the Specifications section.
Item | Specification |
---|---|
Overload Capacity | 110% for 60 seconds, 175% instantaneous |
Output Frequency | 0.01 to 240 Hz |
Control Methods | V/Hz Control Open Loop Vector Control for Permanent Magnet motors |
Motor Types | Squirrel Cage Induction Type Interior Permanent Magnet (IPM) |
Enclosures | NEMA Type 1 / IP20 : 3 – 100 HP 208V and 3 – 250 HP 480V Open Type / IP00 : 125 – 150 HP 208V and 300 – 500 HP 480V |
Ambient Operating Temperature | -10°C to 40°C (14°F to 104°F) |
Global Certification | UL, CSA, RoHS |
Standard I/O | Multi-Function Programmable Digital Inputs (24VDC): 7 Multi-Function Programmable Analog Inputs (0-10VDC or 4-20mA): 2 Fault Relay Output (Form C – 2 Amps at 250VAC max): 1 Multi-Function Programmable Relay Output (Form A – 2 Amps @ 250VAC max): 3 Multi-Function Programmable Analog Outputs (0-10VDC or 4-20mA): 2 24 Vdc, 150 mA Transducer or Transmitter Power Supply for customer use: 1 |
Network Communications | Built-in: BACnet, RS485/422 – Programmable up to 76.8 kbps Optional: |
Z1000 Drive Models & Ratings
Z1000 Drive 208V Standard Drives
Drive Model Number | Rated Input/Output Current (Amps) | Nominal HP | Standard Enclosure |
---|---|---|---|
CIMR-ZU2A0011FAA | 10.6 | 3 | NEMA 1 |
CIMR-ZU2A0017FAA | 16.7 | 5 | |
CIMR-ZU2A0024FAA | 24.2 | 7.5 | NEMA 1 |
CIMR-ZU2A0031FAA | 30.8 | 10 | |
CIMR-ZU2A0046FAA | 46.2 | 15 | NEMA 1 |
CIMR-ZU2A0059FAA | 59.4 | 20 | |
CIMR-ZU2A0075FAA | 74.8 | 25 | NEMA 1 |
CIMR-ZU2A0088FAA | 88 | 30 | |
CIMR-ZU2A0114FAA | 114 | 40 | |
CIMR-ZU2A0143FAA | 143 | 50 | NEMA 1 |
CIMR-ZU2A0169FAA | 169 | 60 | |
CIMR-ZU2A0211FAA | 211 | 75 | |
CIMR-ZU2A0273FAA | 273 | 100 | |
CIMR-ZU2A0343AAA | 343 | 125 | Protected Chassis |
CIMR-ZU2A0396AAA | 396 | 150 |
Z1000 Drive 480V Standard Drives
Drive Model Number | Rated Input/Output Current (Amps) | Nominal HP | Standard Enclosure |
---|---|---|---|
CIMR-ZU4A0005FAA | 4.8 | 3 | NEMA 1 |
CIMR-ZU4A0008FAA | 7.6 | 5 | |
CIMR-ZU4A0011FAA | 11 | 7.5 | |
CIMR-ZU4A0014FAA | 14 | 10 | NEMA 1 |
CIMR-ZU4A0021FAA | 21 | 15 | |
CIMR-ZU4A0027FAA | 27 | 20 | |
CIMR-ZU4A0034FAA | 34 | 25 | NEMA 1 |
CIMR-ZU4A0040FAA | 40 | 30 | |
CIMR-ZU4A0052FAB | 52 | 40 | NEMA 1 |
CIMR-ZU4A0052FAA | 52 | 40 | |
CIMR-ZU4A0065FAA | 65 | 50 | NEMA 1 |
CIMR-ZU4A0077FAA | 77 | 60 | |
CIMR-ZU4A0096FAA | 96 | 75 | |
CIMR-ZU4A0124FAA | 124 | 100 | NEMA 1 |
CIMR-ZU4A0156FAA | 156 | 125 | NEMA 1 |
CIMR-ZU4A0180FAA | 180 | 150 | |
CIMR-ZU4A0240FAA | 240 | 200 | |
CIMR-ZU4A0302FAA | 302 | 250 | NEMA 1 |
CIMR-ZU4A0361AAA | 361 | 300 | Protected Chassis |
CIMR-ZU4A0414AAA | 414 | 350 | Protected Chassis |
CIMR-ZU4A0480AAA | 480 | 400 | |
CIMR-ZU4A0590AAA | 590 | 500 |
Z1000 Drive 600V Standard Drives
Drive Model Number | Rated Input Current (Amps) | Rated Output Current (Amps) | Nominal HP | Standard Enclosure |
---|---|---|---|---|
CIMR-ZU5A0003FAA | 3.6 | 2.7 | 1 & 2 | NEMA 1 |
CIMR-ZU5A0004FAA | 5.1 | 3.9 | 3 | |
CIMR-ZU5A0006FAA | 8.3 | 6.1 | 5 | |
CIMR-ZU5A0009FAA | 12 | 9 | 7.5 | NEMA 1 |
CIMR-ZU5A0011FAA | 16 | 11 | 10 | |
CIMR-ZU5A0017FAA | 23 | 17.5 | 15 | |
CIMR-ZU5A0022FAA | 31 | 22 | 20 | NEMA 1 |
CIMR-ZU5A0027FAA | 38 | 27 | 25 | |
CIMR-ZU5A0032FAA | 45 | 32 | 30 | |
CIMR-ZU5A0041FAA | 44 | 41 | 40 | NEMA 1 |
CIMR-ZU5A0052FAA | 54 | 52 | 50 | |
CIMR-ZU5A0062FAA | 66 | 62 | 60 | |
CIMR-ZU5A0077FAA | 80 | 77 | 75 | NEMA 1 |
CIMR-ZU5A0099FAA | 108 | 99 | 100 | |
CIMR-ZU5A0125AAA | 129 | 125 | 125 | Protected Chassis |
CIMR-ZU5A0145AAA | 158 | 145 | 150 | |
CIMR-ZU5A0192AAA | 228 | 192 | 200 | Protected Chassis |